Use este identificador para citar ou linkar para este item: http://repositorio.undb.edu.br/jspui/handle/areas/643
metadata.dc.type: Trabalho de Conclusão de Curso
Título: Resistência à fadiga cíclica dos instrumentos do sistema X1 e WaveOne
Título(s) alternativo(s): Resistance to cyclic fatigue of X1 system instruments and WaveOne
metadata.dc.creator: OLIVEIRA, Antonio Ítalo
metadata.dc.contributor.advisor1: LEAL, Alex Sandro Mendonça
metadata.dc.contributor.referee1: VALOIS, Érica Martins
metadata.dc.contributor.referee2: CARVALHO, Karinne Travassos Pinto
metadata.dc.description.resumo: A fratura por fadiga cíclica ocorre quando um instrumento é submetido a consecutivas cargas de compressão e tensão no mesmo ponto, na região da curvatura, ocorrendo tensão na porção externa do instrumento e compressão na porção interna ao mesmo tempo. O objetivo deste estudo foi comparar a resistência à fadiga cíclica de instrumentos do sistema X1® Blue (Porto Alegre, RS, Brasil) e WaveOne® Gold (Dentsply Maillefer, Ballaigues, Suíça) em canais curvos artificiais confeccionados em acrílico, através do teste de resistência a fadiga cíclica. O estudo foi caracterizado como sendo experimental e descritivo, utilizando-se o método de abordagem quantitativa e realizado no laboratório pré-clínico de Odontologia do Centro Universitário Unidade de Ensino Superior Dom Bosco (UNDB). Um total de 20 instrumentos de níquel-titânio (NiTi) com Memória de Forma Controlada MFC) foram utilizados, no movimento reciprocante, sendo 10 instrumentos WaveOne® Gold primary (20.07) (Dentsply Maillefer, Ballaigues, Suíça) e 10 instrumentos do sistema X1® (20.06) (Porto Alegre, RS, Brasil). Os resultados demonstraram que os instrumentos do sistema WaveOne® (Dentsply Maillefer, Ballaigues, Suíça) apresentaram melhor resistência à fadiga cíclica quando comparados aos instrumentos do sistema X1®(Porto Alegre, RS, Brasil).
Resumo: Cyclic fatigue fracture occurs when an instrument is subjected to consecutive compression and tension loads at the same point, in the curvature region, with the metal undergoing tension in the outer portion and compression in the inner portion at the same time. This study aims to compare the cyclic fatigue resistance of instruments of the X1® Blue (Porto Alegre, RS, Brazil) and WaveOne® Gold (Dentsply Maillefer, Ballaigues, Suíça) system in artificial curved channels made of acrylic, through the cyclic fatigue resistance test. The study was characterized as being experimental and descriptive, using the method of quantitative approach. The research was carried out in the pre-clinical dentistry laboratory of the University Center Dom Bosco Higher Education Unit. To carry out the experiment, a total of 20 nickel-titanium files were used, being 10 instruments from WaveOne® Gold primary (20.07) (Dentsply Maillefer, Ballaigues, Suíça) and 10 instruments from the X1® system (20.06) (Porto Alegre, RS, Brazil). The results showed that the instruments of the WaveOne® system (Dentsply Maillefer, Ballaigues, Switzerland) presented better resistance to cyclic fatigue when compared to the instruments of the X1® system (Porto Alegre, RS, Brazil).
Palavras-chave: Fratura
Fadiga cíclica
Instrumentos
Sistema X1
Sistema WaveOne
metadata.dc.subject.cnpq: CNPQ::CIENCIAS DA SAUDE
metadata.dc.language: por
metadata.dc.publisher.country: Brasil
Editor: Centro Universitário - UNDB
metadata.dc.publisher.initials: UNDB
metadata.dc.publisher.department: UNDB
Citação: OLIVEIRA, Antonio Ítalo. Resistência à fadiga cíclica dos instrumentos do sistema X1 e WaveOne. São Luís: Centro Universitário UNDB, 2021.
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.undb.edu.br/jspui/handle/areas/643
Data do documento: 30-Nov-2021
Aparece nas coleções:Odontologia

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ANTONIO ITALO OLIVEIRA.pdf726,22 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.